Lucene search

K

Simatic S7-1200 Firmware Security Vulnerabilities

cve
cve

CVE-2012-3037

The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate.

6.6AI Score

0.002EPSS

2012-09-25 11:07 AM
33
cve
cve

CVE-2012-3040

Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.

5.7AI Score

0.002EPSS

2012-10-10 06:55 PM
41
cve
cve

CVE-2013-0700

Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).

6.7AI Score

0.003EPSS

2013-04-22 03:27 AM
36
cve
cve

CVE-2013-2780

Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).

6.7AI Score

0.003EPSS

2013-04-22 03:27 AM
37
cve
cve

CVE-2017-12741

Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.

7.5CVSS

6.6AI Score

0.005EPSS

2017-12-26 04:29 AM
68
cve
cve

CVE-2017-2680

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.

6.5CVSS

6AI Score

0.003EPSS

2017-05-11 01:29 AM
83
cve
cve

CVE-2017-2681

Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.

6.5CVSS

6.1AI Score

0.002EPSS

2017-05-11 10:29 AM
67
2
cve
cve

CVE-2018-13815

A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to...

7.5CVSS

7.2AI Score

0.001EPSS

2018-12-13 04:29 PM
47
cve
cve

CVE-2019-13945

A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-...

6.8CVSS

6.3AI Score

0.001EPSS

2019-12-12 02:15 PM
28
cve
cve

CVE-2020-28400

Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.

7.5CVSS

7.5AI Score

0.002EPSS

2021-07-13 11:15 AM
92
4